Search results
Your search for 闽东电力2025-06-24至2025-07-08上涨原因 returned 67 results.
-
RetroClamps™ used as anode bracelet replacements
Deepwater’s RetroClamps™ were used to provide a CP retrofit for South Pacific flowlines with failing bracelet anodes.
/about/experience-overview/project-review-bulletin-9053/
-
Chevron tank reference electrodes replaced
Deepwater supervised the installation and commissioned the impressed current cathodic protection (ICCP) systems for two Chevron Tahiti float cell vessels.
/about/experience-overview/project-review-bulletin-30004/
-
Two vessels protected by TankGard™
Deepwater designed a tank CP system and provided the equipment to protect a 90” x 30’ low-pressure oil separator on the production deck and a 108” x 13’ flotation cell on the main production deck of an offshore platform.
/about/experience-overview/project-review-bulletin-30037/
-
RetroLinks™ installed on two platforms in the Gulf of Mexico
Deepwater retrofit two platforms in the Gulf of Mexico with RetroLink™ anode strings, one in 125' of water and the other in 57'. The two structures required 31 anode strings.
/about/experience-overview/project-review-bulletin-30194/
-
CP modeling of Truss Spar
A detailed, time-resolved cathodic protection model of a truss spar in 4,500 feet of water in the Gulf of Mexico was constructed from provided CAD files, drawings, documents and photographs.
/about/experience-overview/project-review-bulletin-30118/
-
Enterprise Dock dolphins retrofit
Project review bulletin 30083 (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start': new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0], j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src=…
/about/experience-overview/project-review-bulletin-30083/
-
Modeling remaining CP capacity before retrofitting
Several structures were modeled: Platform A, Platform B, a flare support structure and associated anchor systems. A retrofit was only recommended for one.
/about/experience-overview/project-review-bulletin-9077/
-
RetroClamps™ for rigid jumper monitoring
Deepwater provided six purpose-built RetroClamps™ to be installed on two rigid jumpers for attaching data loggers provided by a third party.
/about/experience-overview/project-review-bulletin-9062/
-
RetroLinks™ installed on 16 structures
Deepwater installed 39 RetroLink™ anode strings on 16 smaller structures in the Gulf of Mexico.
/about/experience-overview/project-review-bulletin-30179/
-
Tower CP modeling
Deepwater constructed a predictive model of a tower located in 1,700 feet of seawater to estimate the remaining life of its corrosion prevention system.
/about/experience-overview/project-review-bulletin-30125/